Energy Type |
Natural Gas - LPG - Electric |
Insulation |
Combination of high temperature insulation bricks - Z block ceramic fiber - Rockwool - Ceraboardd |
Circulatio |
This mechanism generates a vertical air circulation within the furnace which guarantees max.± 5 ºC temperature difference between the top and bottom of the furnace. This mechanism generates a vertical air circulation within the furnace which guarantees max.± 5 ºC temperature difference between the top and bottom of the furnace. |
Control |
Standart Automatic Designed with 2 thermocouples. One for heat control, one for overheat System failures can be monitored by the warning lights located on the control panel PID. temperature control system (electric heating systems) Silent and long lasting SSR system (electric heating systems) Optional Different programs can be entered via programming device. (optional) Touch screen control panel PLC control system with touch screen panel Temperature detection and monitoring from different points in the furnace Process curves can be saved in a computer and print outs can be taken if needed Proportional burner control systems (Natural Gas - LPG) |
Advantages |
Custom designed furnaces according to your needs and expectations. Our furnaces offer long service life as a result of their rigid design and high quality materials. By using high quality insulation materials and adequate number of layers energy costs are decreased significantly.. Bemaktherm will keep supporting his customers in order the run their furnaces flawlessly |
Optional |
Hydraulic lid mechanism for the bigger systems (hydraulic lift up - manual pulling aside) |
Nitrogen gas was introduced into the furnace to prevent oxidation.
The cover rises up with a hydraulic mechanism and is pulled to the side manually
INNER DIMENSIONS | : Ø2450 mm x h 2250 mm |
ENERGY TYPE | : Natural Gas |
MAX. TEMPERATURE | : 750 °C |
CAPACITY | : 20 tons / charge |
CONTROL | : Automatic - Programmable Lid is lifted up with a crane before loading |
The furnace can be used for both tempering and annealing processes.
The lid is lifted with a hydraulic mechanism and is pulled to the side manually.
Nitrogen gas can be used to prevent oxidation.